WSP3312I UNIVERSAL COUNTER
BDT 119,467/-
Product Details
Brand: MCP
Model: WSP3312I
Country Of Origin: China
Features
-
High-performance AVR CPU, LSI, and CPLD for reliability
-
Single time interval and pulse width measurement
-
Automatic statistical functions for frequency measurement: mean, max, min, delta, absolute deviation, relative deviation (PPM), standard deviation, Allan variance
-
Average measurement function for improved accuracy of time interval, pulse width, phase, duty cycle
-
Set time gate totalizing and manual totalizing
-
Automatic storage of current values, zero data loss
-
Save up to 9 measurement setups
-
Interfaces: USB, RS232, Centronics printer
-
VFD display, compact and ergonomic design
Technical Data
| Specification | WSP3312 |
|---|---|
| Functions | Frequency, Time Interval, Period, Frequency Ratio, Totalize, Pulse Width, Duty Cycle, Phase, Self-calibration |
| Frequency Range (CH A & B) | 0.14mHz–50MHz/100MHz |
| Frequency Range (CH C) | 100MHz–500MHz (I), 100MHz–1.5GHz (II), 100MHz–2.5GHz (III), 100MHz–3.5GHz (IV) |
| Input Voltage | 30mVrms–1.5Vrms (<100MHz); 50mVrms–1.5Vrms (100MHz–1.5GHz); 30mVrms–1Vrms (1.5–3GHz) |
| Period Range | 20ns/10ns–7000s, 20ns resolution |
| Time Interval Range | 40ns–7000s, 20ns resolution |
| Phase Range | 0–359° |
| Pulse Width Range | ≥20ns (cycle <100s) |
| Duty Cycle Range | 1–99% (cycle <100s) |
| Measurement Accuracy | ±2×10⁻⁷ / Gate time (s) |
| Frequency Resolution | 7.5 digits / Gate time (s) |
| Totalize Capacity | 1×10⁸ |
| Coupling Mode | CH A/B: AC/DC; CH C: AC |
| Input Impedance | 1MΩ/45pF or 50Ω |
| Time Base Stability | 10MHz, ±1×10⁻⁶/day |
| Power Supply | 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz |
| Dimensions | 255×100×370mm |
| Weight | 3kg |
| Functions | Frequency, Time Interval, Period, Frequency Ratio, Totalize, Pulse Width, Duty Cycle, Phase, Self-calibration |
| Frequency Range (CH A & B) | 0.14mHz–50MHz/100MHz |
| Frequency Range (CH C) | 100MHz–500MHz (I), 100MHz–1.5GHz (II), 100MHz–2.5GHz (III), 100MHz–3.5GHz (IV) |
| Input Voltage | 30mVrms–1.5Vrms (<100MHz); 50mVrms–1.5Vrms (100MHz–1.5GHz); 30mVrms–1Vrms (1.5–3GHz) |
| Period Range | 20ns/10ns–7000s, 20ns resolution |
| Time Interval Range | 40ns–7000s, 20ns resolution |
| Phase Range | 0–359° |
| Pulse Width Range | ≥20ns (cycle <100s) |
| Duty Cycle Range | 1–99% (cycle <100s) |
| Measurement Accuracy | ±2×10⁻⁷ / Gate time (s) |
| Frequency Resolution | 7.5 digits / Gate time (s) |
| Totalize Capacity | 1×10⁸ |
| Coupling Mode | CH A/B: AC/DC; CH C: AC |
| Input Impedance | 1MΩ/45pF or 50Ω |
| Time Base Stability | 10MHz, ±1×10⁻⁶/day |
| Power Supply | 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz |
| Dimensions | 255×100×370mm |
| Weight | 3kg |
Features
-
High-performance AVR CPU, LSI, and CPLD for reliability
-
Single time interval and pulse width measurement
-
Automatic statistical functions for frequency measurement: mean, max, min, delta, absolute deviation, relative deviation (PPM), standard deviation, Allan variance
-
Average measurement function for improved accuracy of time interval, pulse width, phase, duty cycle
-
Set time gate totalizing and manual totalizing
-
Automatic storage of current values, zero data loss
-
Save up to 9 measurement setups
-
Interfaces: USB, RS232, Centronics printer
-
VFD display, compact and ergonomic design
Technical Data
| Specification | WSP3312 |
|---|---|
| Functions | Frequency, Time Interval, Period, Frequency Ratio, Totalize, Pulse Width, Duty Cycle, Phase, Self-calibration |
| Frequency Range (CH A & B) | 0.14mHz–50MHz/100MHz |
| Frequency Range (CH C) | 100MHz–500MHz (I), 100MHz–1.5GHz (II), 100MHz–2.5GHz (III), 100MHz–3.5GHz (IV) |
| Input Voltage | 30mVrms–1.5Vrms (<100MHz); 50mVrms–1.5Vrms (100MHz–1.5GHz); 30mVrms–1Vrms (1.5–3GHz) |
| Period Range | 20ns/10ns–7000s, 20ns resolution |
| Time Interval Range | 40ns–7000s, 20ns resolution |
| Phase Range | 0–359° |
| Pulse Width Range | ≥20ns (cycle <100s) |
| Duty Cycle Range | 1–99% (cycle <100s) |
| Measurement Accuracy | ±2×10⁻⁷ / Gate time (s) |
| Frequency Resolution | 7.5 digits / Gate time (s) |
| Totalize Capacity | 1×10⁸ |
| Coupling Mode | CH A/B: AC/DC; CH C: AC |
| Input Impedance | 1MΩ/45pF or 50Ω |
| Time Base Stability | 10MHz, ±1×10⁻⁶/day |
| Power Supply | 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz |
| Dimensions | 255×100×370mm |
| Weight | 3kg |
The WSP3312 Universal Counter is a versatile instrument for precision measurement of frequency, time interval, period, duty cycle, and phase. With advanced statistical functions including Allan variance and PPM deviation, it ensures highly accurate results for laboratory and R&D applications. Supporting frequency ranges up to 3.5GHz (depending on model), the WSP3312 offers AC/DC coupling, multiple input channels, and a stable 10MHz time base. Compact and reliable, it features USB, RS232, and printer interfaces, making it ideal for professional test environments.
Asked by Visitor
100% Viscose Fabric.
Thank You.
Asked by Visitor