CQ5660 ANALOG OSCILLOSCOPE
BDT 78,985/-
Product Details
Brand: MCP
Model: CQ5660
Country Of Origin: China
Features
-
Digital sweep & vertical selection
-
Surface mounting technology
-
TV synchronization
-
CH1 output lock
-
ALT triggering function
-
Z-axis input
Technical Data
-
CRT: 6" rectangle, internal graticule, accelerating voltage 12kV, continuously adjustable intensity/focus, front-panel trace rotation, 1mV/DIV–5V/DIV ±3% (12 steps, 1-2-5 sequence), trimming ratio ≥2.5:1
-
Vertical System: Bandwidth DC(AC 10Hz)–40MHz (CQ5640), DC(AC 10Hz)–60MHz (CQ5660); rise time ≤9.5ns (CQ5640), ≤5.83ns (CQ5660); input impedance 1MΩ ±3%, 25pF ±5pF; coupling DC/GND/AC; max input 400V; modes CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 inverse
-
Horizontal System: Sweep 0.1µs–0.5s/DIV; accuracy ±3%, ±5% at X10MAG; trimming ratio ≥2.5:1; sweep magnification ×10MAG; max sweep time 10ms/DIV; modes SINGLE, AUTO, NORM, TV-T, TV-H; sources ALT, CH1, CH2, EXT, LINE; polarity selectable
-
Trigger System: Sources CH1, CH2, ALT, EXT; sensitivity ranges (0.5DIV–3DIV depending on frequency); EXT 0.2DIV–0.8DIV; TV sync pulse 1DIV; input impedance 1MΩ ±3%, 75pF ±5pF; max input 300V at 1kHz
-
Frequency Counter: 6-digit LED display; accuracy 1Hz (0–1MHz), 10Hz (1–10MHz), 100Hz (10–60MHz); sensitivity same as trigger
-
X-Y Operation: Sensitivity 5mV–5V/DIV ±5%; bandwidth DC–500kHz; phase difference ≤3° (DC–50kHz); sensitivity 5Vp-p; polarity negative-going increases intensity
-
Z Axis: Input impedance 47kΩ; usable DC–2MHz; max input 30V at 1kHz
-
Calibration: 2Vp-p ±2%, 1kHz ±2%, square wave
-
Power Source: 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz
-
Dimensions: 316 × 132 × 410 mm
-
Weight: 7.8 kg
-
Accessories: Manual, fuse, power cable, 2 probes
| CRT: | 6" rectangle, internal graticule, accelerating voltage 12kV, continuously adjustable intensity/focus, front-panel trace rotation, 1mV/DIV–5V/DIV ±3% (12 steps, 1-2-5 sequence), trimming ratio ≥2.5:1 |
| Vertical System: | Bandwidth DC(AC 10Hz)–40MHz (CQ5640), DC(AC 10Hz)–60MHz (CQ5660); rise time ≤9.5ns (CQ5640), ≤5.83ns (CQ5660); input impedance 1MΩ ±3%, 25pF ±5pF; coupling DC/GND/AC; max input 400V; modes CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 inverse |
| Horizontal System: | Sweep 0.1µs–0.5s/DIV; accuracy ±3%, ±5% at X10MAG; trimming ratio ≥2.5:1; sweep magnification ×10MAG; max sweep time 10ms/DIV; modes SINGLE, AUTO, NORM, TV-T, TV-H; sources ALT, CH1, CH2, EXT, LINE; polarity selectable |
| Trigger System: | Sources CH1, CH2, ALT, EXT; sensitivity ranges (0.5DIV–3DIV depending on frequency); EXT 0.2DIV–0.8DIV; TV sync pulse 1DIV; input impedance 1MΩ ±3%, 75pF ±5pF; max input 300V at 1kHz |
| Frequency Counter: | 6-digit LED display; accuracy 1Hz (0–1MHz), 10Hz (1–10MHz), 100Hz (10–60MHz); sensitivity same as trigger |
| X-Y Operation: | Sensitivity 5mV–5V/DIV ±5%; bandwidth DC–500kHz; phase difference ≤3° (DC–50kHz); sensitivity 5Vp-p; polarity negative-going increases intensity |
| Z Axis: | Input impedance 47kΩ; usable DC–2MHz; max input 30V at 1kHz |
| Calibration: | 2Vp-p ±2%, 1kHz ±2%, square wave |
| Power Source: | 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz |
| Dimensions: | 316 × 132 × 410 mm |
| Weight: | 7.8 kg |
| Accessories: | Manual, fuse, power cable, 2 probes |
Features
-
Digital sweep & vertical selection
-
Surface mounting technology
-
TV synchronization
-
CH1 output lock
-
ALT triggering function
-
Z-axis input
Technical Data
-
CRT: 6" rectangle, internal graticule, accelerating voltage 12kV, continuously adjustable intensity/focus, front-panel trace rotation, 1mV/DIV–5V/DIV ±3% (12 steps, 1-2-5 sequence), trimming ratio ≥2.5:1
-
Vertical System: Bandwidth DC(AC 10Hz)–40MHz (CQ5640), DC(AC 10Hz)–60MHz (CQ5660); rise time ≤9.5ns (CQ5640), ≤5.83ns (CQ5660); input impedance 1MΩ ±3%, 25pF ±5pF; coupling DC/GND/AC; max input 400V; modes CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 inverse
-
Horizontal System: Sweep 0.1µs–0.5s/DIV; accuracy ±3%, ±5% at X10MAG; trimming ratio ≥2.5:1; sweep magnification ×10MAG; max sweep time 10ms/DIV; modes SINGLE, AUTO, NORM, TV-T, TV-H; sources ALT, CH1, CH2, EXT, LINE; polarity selectable
-
Trigger System: Sources CH1, CH2, ALT, EXT; sensitivity ranges (0.5DIV–3DIV depending on frequency); EXT 0.2DIV–0.8DIV; TV sync pulse 1DIV; input impedance 1MΩ ±3%, 75pF ±5pF; max input 300V at 1kHz
-
Frequency Counter: 6-digit LED display; accuracy 1Hz (0–1MHz), 10Hz (1–10MHz), 100Hz (10–60MHz); sensitivity same as trigger
-
X-Y Operation: Sensitivity 5mV–5V/DIV ±5%; bandwidth DC–500kHz; phase difference ≤3° (DC–50kHz); sensitivity 5Vp-p; polarity negative-going increases intensity
-
Z Axis: Input impedance 47kΩ; usable DC–2MHz; max input 30V at 1kHz
-
Calibration: 2Vp-p ±2%, 1kHz ±2%, square wave
-
Power Source: 110–127VAC ±10%, 220–240VAC ±10%, 50/60Hz ±2Hz
-
Dimensions: 316 × 132 × 410 mm
-
Weight: 7.8 kg
-
Accessories: Manual, fuse, power cable, 2 probes
The CQ5640/CQ5660 analog oscilloscope is a high-performance dual-channel instrument designed for precision waveform analysis. Featuring bandwidths up to 60MHz, fast rise times, and versatile triggering options, it ensures accurate signal capture for both laboratory and industrial applications. With a 6-digit LED frequency counter, X-Y operation, and TV synchronization, this oscilloscope delivers reliable measurement capability. Compact dimensions, durable construction, and included probes make it an ideal choice for engineers, technicians, and educational labs.