CQ5030 ANALOG OSCILLOSCOPE
CQ5030 ANALOG OSCILLOSCOPE

BDT 42,982/-

Model: CQ5030

Product ID: 100286

Product Details

Brand: MCP
Model: CQ5030
Country Of Origin: China 

Features

  • High sensitivity: 1mV/div

  • Wide vertical range: 20V/div

  • Dual channel: 20MHz (CQ5020) / 30MHz (CQ5030)

  • TV synchronization

  • Z‑axis input

  • Vertical mode triggering

  • CH1 output

Technical Data

CRT

  • Type: 6" rectangle, internal graticule with 0%, 10%, 90%, 100% marks

  • Display area: 8 × 10 div (1 div = 10mm)

  • Accelerating voltage: 1.9kV (CQ5020), 2kV (CQ5030)

  • Intensity/focus: Continuously adjustable

  • Trace rotation: Front panel adjustable

  • Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%

  • Bandwidth (–3dB): DC–20MHz (CQ5020), DC–30MHz (CQ5030)

  • Rise time: ≤17.5ns (CQ5020), ≤12ns (CQ5030)

Vertical System

  • Input impedance: ~1MΩ ±3%, 30pF ±5pF

  • Input coupling: DC, GND, AC

  • Max input voltage: 400V (DC + AC peak, ≤1kHz)

  • Vertical modes: CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 inverse

  • CH1 signal output: 25mV/div, 50Ω, 20Hz–10MHz (–3dB)

Horizontal System

  • Sweep time: 0.2µs/div–0.2s/div (19 steps)

  • Sweep accuracy: ±3%, ±5% at ×10MAG

  • Sweep magnification: ×10MAG

  • Max sweep time: 20ns/div

  • Modes: AUTO, NORM, TV

  • Sources: VERT‑MODE, CH1, EXT, LINE

  • Coupling: AC

  • Polarity: “+” or “–”

Trigger System

  • Sensitivity:

    • 10Hz–10MHz: INT 0.5div, EXT 0.2

    • 10MHz–20MHz: INT 1.5div, EXT 0.8

    • 20MHz–30MHz: INT 1.5div, EXT 0.2

  • TV sync pulse: 1div or 1V (EXT)

  • External trigger input impedance: 1MΩ ±3%, 25pF ±5pF

  • Max input voltage: 400V

X‑Y Operation

  • Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%

  • Bandwidth (–3dB): CQ5020 DC–500kHz, CQ5030 DC–1MHz

  • Phase difference: ≤3° (DC–50kHz)

Axis Z

  • Sensitivity: 5V

  • Polarity: Negative input increases intensity

  • Input impedance: 20kΩ–30kΩ

  • Frequency range: DC–2MHz

  • Max input voltage: 30V (DC + AC peak)

Calibration

  • Signal: 1kHz ±0.5Vp‑p square wave

Power Source

  • 110–127VAC ±10%, 220–240VAC ±10%

  • 50Hz ±2Hz / 60Hz ±2Hz

Dimensions

  • 316(W) × 132(H) × 410(D) mm

Weight

  • 7.8kg

Accessories

  • Operation manual, fuse, power cable, two probes

Professional Service
Quick Response
24/7 Customer Support
CRT Type: 6" rectangle, internal graticule with 0%, 10%, 90%, 100% marks
CRT Display area: 8 × 10 div (1 div = 10mm)
CRT Accelerating voltage: 1.9kV (CQ5020), 2kV (CQ5030)
CRT Intensity/focus: Continuously adjustable
CRT Trace rotation: Front panel adjustable
CRT Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%
CRT Bandwidth (–3dB): DC–20MHz (CQ5020), DC–30MHz (CQ5030)
CRT Rise time: ≤17.5ns (CQ5020), ≤12ns (CQ5030)
Vertical System Input impedance: ~1MΩ ±3%, 30pF ±5pF
VS Input coupling: DC, GND, AC
VS Max input voltage: 400V (DC + AC peak, ≤1kHz)
VS Vertical modes: CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 inverse
VS CH1 signal output: 25mV/div, 50Ω, 20Hz–10MHz (–3dB)
Horizontal System Sweep time: 0.2µs/div–0.2s/div (19 steps)
HS Sweep accuracy: ±3%, ±5% at ×10MAG
HS Sweep magnification: ×10MAG
HS Max sweep time: 20ns/div
HS Modes: AUTO, NORM, TV
HS Sources: VERT‑MODE, CH1, EXT, LINE
HS Coupling: AC
HS Polarity: “+” or “–”
Trigger System Sensitivity: 10Hz–10MHz: INT 0.5div, EXT 0.2

10MHz–20MHz: INT 1.5div, EXT 0.8

20MHz–30MHz: INT 1.5div, EXT 0.2
TS TV sync pulse: 1div or 1V (EXT)
TS External trigger input impedance: 1MΩ ±3%, 25pF ±5pF
TS Max input voltage: 400V
X‑Y Operation Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%
X‑Y Operation Bandwidth (–3dB): CQ5020 DC–500kHz, CQ5030 DC–1MHz
X‑Y Operation Phase difference: ≤3° (DC–50kHz)
Axis Z Sensitivity: 5V
Axis Z Polarity: Negative input increases intensity
Axis Z Sensitivity: 5V
Axis Z Polarity: Negative input increases intensity
Axis Z Input impedance: 20kΩ–30kΩ
Axis Z Frequency range: DC–2MHz
Axis Z Max input voltage: 30V (DC + AC peak)
Calibration Signal: 1kHz ±0.5Vp‑p square wave
Power Source: 110–127VAC ±10%, 220–240VAC ±10%

50Hz ±2Hz / 60Hz ±2Hz
Dimensions: 316(W) × 132(H) × 410(D) mm
Weight: 7.8kg
Accessories: Operation manual, fuse, power cable, two probes

Features

  • High sensitivity: 1mV/div

  • Wide vertical range: 20V/div

  • Dual channel: 20MHz (CQ5020) / 30MHz (CQ5030)

  • TV synchronization

  • Z‑axis input

  • Vertical mode triggering

  • CH1 output

Technical Data

CRT

  • Type: 6" rectangle, internal graticule with 0%, 10%, 90%, 100% marks

  • Display area: 8 × 10 div (1 div = 10mm)

  • Accelerating voltage: 1.9kV (CQ5020), 2kV (CQ5030)

  • Intensity/focus: Continuously adjustable

  • Trace rotation: Front panel adjustable

  • Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%

  • Bandwidth (–3dB): DC–20MHz (CQ5020), DC–30MHz (CQ5030)

  • Rise time: ≤17.5ns (CQ5020), ≤12ns (CQ5030)

Vertical System

  • Input impedance: ~1MΩ ±3%, 30pF ±5pF

  • Input coupling: DC, GND, AC

  • Max input voltage: 400V (DC + AC peak, ≤1kHz)

  • Vertical modes: CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 inverse

  • CH1 signal output: 25mV/div, 50Ω, 20Hz–10MHz (–3dB)

Horizontal System

  • Sweep time: 0.2µs/div–0.2s/div (19 steps)

  • Sweep accuracy: ±3%, ±5% at ×10MAG

  • Sweep magnification: ×10MAG

  • Max sweep time: 20ns/div

  • Modes: AUTO, NORM, TV

  • Sources: VERT‑MODE, CH1, EXT, LINE

  • Coupling: AC

  • Polarity: “+” or “–”

Trigger System

  • Sensitivity:

    • 10Hz–10MHz: INT 0.5div, EXT 0.2

    • 10MHz–20MHz: INT 1.5div, EXT 0.8

    • 20MHz–30MHz: INT 1.5div, EXT 0.2

  • TV sync pulse: 1div or 1V (EXT)

  • External trigger input impedance: 1MΩ ±3%, 25pF ±5pF

  • Max input voltage: 400V

X‑Y Operation

  • Sensitivity & accuracy: 5mV/div–20V/div ±3%, 1mV/div–2mV/div ±5%

  • Bandwidth (–3dB): CQ5020 DC–500kHz, CQ5030 DC–1MHz

  • Phase difference: ≤3° (DC–50kHz)

Axis Z

  • Sensitivity: 5V

  • Polarity: Negative input increases intensity

  • Input impedance: 20kΩ–30kΩ

  • Frequency range: DC–2MHz

  • Max input voltage: 30V (DC + AC peak)

Calibration

  • Signal: 1kHz ±0.5Vp‑p square wave

Power Source

  • 110–127VAC ±10%, 220–240VAC ±10%

  • 50Hz ±2Hz / 60Hz ±2Hz

Dimensions

  • 316(W) × 132(H) × 410(D) mm

Weight

  • 7.8kg

Accessories

  • Operation manual, fuse, power cable, two probes

The CQ5020 / CQ5030 Oscilloscopes are high‑performance dual‑channel instruments designed for advanced laboratory and educational applications. Offering bandwidths of 20MHz and 30MHz respectively, they deliver precise waveform analysis with ultra‑high sensitivity down to 1mV/div. Equipped with TV synchronization, Z‑axis input, and versatile vertical modes, these oscilloscopes provide flexibility for complex signal testing. With robust triggering, X‑Y operation, and CH1 output, they are ideal for engineers, technicians, and students requiring reliable and accurate measurement tools.

Question & Answer
Customer Questions
Q:
But material
Asked by Visitor
A:
Dear Customer,
100% Viscose Fabric.

Thank You.
Answered By: Karam Company Ltd.   21.11.2020
Q:
আপনার পণ্য কেমন ভাবে অর্ডার করবো?
Asked by Visitor
Review
Customer Reviews
No reviews given yet.
Your Review
Select rating
Your review has been submitted successfully.